Doremi Maintenance Program Notification Pop Up

Doremi Maintenance Program Notification Pop Up

Skip to Main Content

Doremi Maintenance Program Notification Pop Up

Feb 18, 2021Knowledge

Question
This article applies to DCP2000, DCP-2K4, ShowVault, IMS1000, IMS2000 and IMS3000.

What is the Maintenance Program notification pop-up regarding?
Answer

In the 2.4.X software release, we added a Maintenance reminder pop up to ensure the maintenance checks and visit is performed once a year.

This pop up message is only a warning and will not affect the playback of the show. The error log can be found in drmreport.tgz\doremi\log\maintenance.log and looks like this:

[Thu Nov 29 13:52:11 2012]: DOREMI_MAINTENANCE_PROGRAM error event: MaintenanceStatus Severity=Error Group=ScreenManagementSystem Operation=DOREMI_MAINTENANCE_PROGRAM Last=2008-11-05T15:52:32+01:00 Error=-1120 Warning=-1240"

This pop up message will be shown:
 "The Doremi Maintenance program has not been performed on time. The system may malfunction. Call Doremi tech support"
User-added image
User-added image
 
The procedure to stop the message appearing every day should be followed after the maintenance visit to check server operation, run upgrades, check and clean fans etc is:
  • Go to Menu>Control Panel>Log Operator Maintenance.
  • Record a new message under "DOREMI_MAINTENANCE_PROGRAM"

User-added image

Similar messages will appear regarding the Secure Clock Battery Replacement, it is very important this is done on time. See the following for more information: Battery Replacement Procedure for Dolphin DCI 1.2.


This article appears in the Dolby knowledge base for cinema products.
--



    • Related Articles

    • Doremi Showvault/DCP-2000 Power Switch Location

      The power switch for the Doremi Showvault/DCP-2000 is located inside of the RAID drive bay on the left side.
    • Doremi DCP-2000/Showvault - Adding VNC into a server

      VNC into a server     Created on Thursday, 13 December 2012 17:17 To be able to VNC into a server, the server must have had the pkg ingested.  This is not done by default in the factory.  Install pkg: dcp2000_X11vnc-1.10.pkg or for SW 2.6.XX and ...
    • Power Switch Location for DCP-2000 and Showvault

      A common question that we get asked is "how do I turn on my Doremi Showvault or DCP-2000 series server?" Doremi did an amazing job of hiding the power switch from the user. The short answer is that the power switch is behind the front hinged door ...
    • Dolby/Doremi Server Date reset to 1900's

      There is a known bug in the Security Manager software of certain Doremi/Dolby server models. This bug affects DCP-2000, ShowVault, IMS1000 and IMS2000 servers and some of their variants. Dolby refers to this bug as the Y2K24 bug as what it does is ...
    • Dolby/Doremi Cinema Server Qualified Hard Drive List

      The attached document contains a list of approved/tested replacement hard drives for Dolby/Doremi servers.Dolby/Doremi Approved Drives