This problem is caused by the TI Link Decryptor, better known as the Enigma board.  When using a projector with a "traditional" type of server (as opposed to an IMB/IMS type server), the signal coming from the external server is encrypted and decrypted by the "link decryptor" (enigma) within the projector.  The security certificate within the link decryptor is maintained by a battery that is recharged in normal use.  If the projector is left powered down for a long period of time the battery loses its charge and the certificate is lost.  This also can happen as the board ages.  After 5+ years of operation the battery may stop taking a charge.  We've seen this happen as early as 3 years.  In any case the certificate is lost and the link decryptor must be replaced.

It should be noted that if the projector is using an IMB server for digital content, the Enigma board is not being used.  The simple and free fix is to depricate the 80LBxx board into a 80DSxx board.  This turns off the Enigma module on the board and allows the board to function as a non-protected input board.  This procedure is done through the DCC.

1. Check connection between ICP PWB and Mother PWB.
2. Check connection between SIB PWB and ENIGMA PWB.
3. Check LAN Connector of Moter PWB.
4. Check LAN IP address of SIB PWB.
5. Check Frimwarea version of both SIB PWB and ENIGMA PWB.

Associated Errors

400         Enigma Comm Fail(Param1Param2Param3:Param4)

410         System Error                     

411         Self Test Error                   

412         Install Release Package Error                      

413         Load Release Package Error                        

414         TI Login List Package Error                           

415         Security Officer Login List Package Error                

419         Certificate or Key Error                  

426         User Loader Integrity Error                          

427         Main Application Integrity Error                

428         RNG Hardware Integrity Error                    

429         DRNG Algorithm Integrity Error                 

430         RSA Algorithm Integrity Error                     

431         AES Algorithm Integrity Error                     

432         HMAC Algorithm Integrity Error                

433         SHA Algorithm Integrity Error                     

434         TLS Integrity Error                           

435         FPGA Configuration Integrity Error                           

436         FPGA CineLink 2 Decryption Integrity Error                                                  

442         FPGA Configuration Error                             

443         FPGA Temperature out of range                

446         RNG Hardware Duplicate Output Error                   

447         DRNG Algorithm Duplicate Output Error                           

458         Self Test User Loader Integrity Error                        

459         Self Test Main Application Integrity Error                              

460         Self Test RNG Hardware Integrity Error                  

461         Self Test DRNG Algorithm Integrity Error                

462         Self Test RSA Algorithm Integrity Error                   

463         Self Test AES Algorithm Integrity Error                    

464         Self Test HMAC Algorithm Integrity Error                              

465         Self Test SHA Algorithm Integrity Error                   

466         Self Test TLS Integrity Error                         

467         Self Test FPGA Configuration Integrity Error                         

468         Self Test FPGA CineLink. 2 Decryption Integrity Error                                          

477         Security Battery Event                  

478         Software Commanded Zeroization                          

            



    • Related Articles

    • NEC Cinema equipment installations best practice guidance for extended Off times (ver1 3)

      Guidance for protecting your NEC projection equipment when your theatre/post production installation might be closed for a while Due to the actual force majeure of closing cinema installations for an unknown period of time, we would like to provide ...
    • 2010 Incorrect power-off Error

      The 2010 incorrect power-off error is an error code that presents in some late Series 2 as well as NEC laser projectors. Quite simply put, this error presents when the projector did not go through a proper power off sequence, such as a power failure ...
    • NEC Projectors - Preparation for a temporary Shutdown

      For NC1200C, NC2000C, NC3200S, NC3240S, NC900C, NC1100L: If there is an Enigma card (PN# NC-80LB01) in these units, please make sure it is fully charged (48 hrs. of power On should be sufficient). The Enigma charge normally remains for about 6 month, ...
    • Lamp replacement NEC NC Series digital projectors

      This video, provided by Philips, describes the lamp installation procedure on NEC series 2 projectors. NEC Series 2 Lamp Installation Procedure FYI - Philips digital projection lamps are now sold under the Lighting Technologies International (LTI) ...
    • NEC S2 Projector Displaying 3xx Error