A common question that we get asked is "how do I turn on my Doremi Showvault or DCP-2000 series server?" Doremi did an amazing job of hiding the power switch from the user. The short answer is that the power switch is behind the front hinged door that covers the RAID array. On most servers this door is locked with a key.
Doremi used two different chassis frames for their servers. One was a 3ru high chassis (5.25" or 133.3mm) and the other was 4ru high (7" or 178mm).
Typical 3ru chassis

On the 3ru chassis, the power switch is behind the door with the lock on the right.
This picture shows a typical 4ru chassis
As before, the power switch is located behind the locked door on the right.
An important note is that, with the exception of an emergency shutdown, such as a recovery from a lockup, the server must be shutdown using the software interface. With the original (traditional) interface this is found by clicking on the MENU button in the lower left corner then clicking on the LOGOUT button.
Once the LOGOUT button has been clicked, the screen will present a popup with SHUTDOWN LOGOUT and RESTART options.
Related Articles
Doremi Showvault/DCP-2000 Power Switch Location
The power switch for the Doremi Showvault/DCP-2000 is located inside of the RAID drive bay on the left side.
Doremi DCP-2000/Showvault - Adding VNC into a server
VNC into a server Created on Thursday, 13 December 2012 17:17 To be able to VNC into a server, the server must have had the pkg ingested. This is not done by default in the factory. Install pkg: dcp2000_X11vnc-1.10.pkg or for SW 2.6.XX and ...
Checking a ShowVault, DCP-2000 or DCP-2K4 security certificate expiration date
The original security certificate expiration date for Doremi ShowVault, DCP-2000 or DCP-2K4 servers was set to expire on November 30, 2025. Once expired, the server will no longer be able to play secure content. Dolby issued a technical bulletin in ...
Dolby DSS-200 Power Switch for Hard Reboot
The Dolby DSS digital cinema server was designed deliberately without a front panel power switch. This was done by design to prevent accidental turn-off during a presentation. There are times, however, when a full power cycle is needed to clear a ...
Doremi Maintenance Program Notification Pop Up
Skip to Main Content Doremi Maintenance Program Notification Pop Up Feb 18, 2021•Knowledge Question This article applies to DCP2000, DCP-2K4, ShowVault, IMS1000, IMS2000 and IMS3000. What is the Maintenance Program notification pop-up regarding? ...